// products · channel → instrument → system

One measurement problem,
three ways to buy it.

Every Tremon product is the same NDIR core at a different level of integration: the channel you build into your own instrument, the instrument you install in the field, or the system that collects, alarms and reports. Pick by the rule you have to satisfy — or by the gas.

Start here

Which rule are you buying for?

Regulation → gas → product. Dates and obligations are explained on the Regulation → measurement page.

Regulation / obligationGasTremon product
F-gas · Reg. (EU) 2024/573
SF₆ switchgear leak-check exemption · room / leak monitoring
SF₆ · refrigerantsDM-91 density monitor with alert · IR·SF₆ transmitter · GDC-S52 multi-point sampling for GIS rooms · IR·OEM SF₆ channel
Methane · Reg. (EU) 2024/1787
LDAR surveys · continuous CH₄ monitoring · MRV
CH₄ (ppm → %LEL)TRM-EX-IR field analyzer (Ex) · IR·OEM CH₄ channel for survey instruments
Biomethane · REPowerEU 35 bcm
digester control · grid-injection gas quality
CH₄ + CO₂TRM-PGA process analyzer (rack / wall) · IR·OEM CO₂/CH₄ channel for skids
Industrial emissions · Dir. (EU) 2024/1785
permit monitoring · CEMS · QAL
CO₂ · CO · SO₂ · N₂OTRM-PGA multi-channel process analyzer · IR·OEM channels · GDC controller to SCADA
CBAM · ETS
verified actual emissions vs default values
CO₂TRM-PGA process analyzer + traceable calibration record · IR·OEM CO₂ channel
Buildings · EPBD 2024/1275
indoor-air-quality measuring & control devices
CO₂IR·OEM CO₂ channel for building-automation makers
Workplace safety · ATEX / OEL
toxic · combustible · O₂ in hazardous areas
multi-gasTRM-EX (E / CT / IR / SMC) · GDC alarm controller · GDC-S52 sampling · GASPOD cabinet
Catalogue

L1OEM NDIR channels — into your instrument

The sensing core with an interface contract. In-house 2-beam optics with reference channel and heated cell; calibration traceable to national primary gas standards. Delivered as OEM board or benched module, scoped to your gas, range and matrix.

IR·OEM
OEM NDIR channel · one gas or several · board / bench / transmitter
OEM · MADE TO SPEC
biomethaneCEMS · IEDF-gas 2024/573IAQ · EPBDCBAM · process
gasesCO₂ · CO · CH₄ · C₂H₄ · N₂O · SO₂ · NH₃ · SF₆ · SO₂F₂ · CH₃Br · biogas (CH₄/CO₂)
F-gas / refrigerantsSF₆ · R-134a · R-125 · R-22 · R-227ea · R-407c · R-12 · R-113
rangesCO₂ 100 ppm → 100 vol% · CO 2000 ppm → 100 vol% · CH₄ 2000 ppm → 100 vol% · SF₆ 50 ppm → 100 vol% · N₂O / SO₂ / C₂H₄ / NH₃ 200 ppm → 1 vol%
optics2-beam + reference channel · heated cell · T · P · H₂O compensation
performanceLOD 2 % FS · linearity ±2 % · T90 < 30 s · cross-sensitivity < 4 %
interfaceModbus RTU / TCP · Ethernet · UART · RS-232/485 · CAN · LoRa · 4–20 mA
calibrationtraceable ISO 17025 method · VSL · record per unit
not NDIRO₂ · H₂ · N₂ → electrochemical / thermocatalytic channels of TRM-EX

L2Field instruments — install and connect

Complete transmitters and transducers with datasheet, manual and a per-unit calibration record — the number you defend in an audit.

DM-91
multifunction density transducer · SF₆
F-gas 2024/573leak-check exemptionswitchgear retrofit
Tremon DM-91
measuresdensity · pressure · temperature · humidity
gasesSF₆ · N₂ · CF₄ · O₂ · CO₂ · Novec™ 4710 · He · Ar · mixtures
accuracy±0.2 % URL pressure/density · ±0.2 °C · ±5 % RH
ranges0.6 / 1.2 / 1.6 / 2.2 MPa abs · 3-year calibration interval
interfaceRS-485 Modbus RTU · LCD opt. · M12 / cable
buildIP68 · ≤30×125 mm · ≤0.5 kg · −60…+85 °C
TRM-PGA
process NDIR gas analyzer · rack / wall
biomethaneCEMS · IEDCBAM · process
Tremon TRM-PGA
channels1–7 gases per heated stainless cuvette · no moving parts
rangesCO₂ · CO · CH₄ · SF₆ · N₂O · SO₂ · C₂H₄ · NH₃ · biogas — ppm → 100 vol%
performanceLOD < 2 % FS · linearity ±2 % · T90 < 30 s · cross-sens. < 4 %
interfaceRS-485 Modbus RTU · Ethernet Modbus TCP · USB service · µSD log
versionsTRM-PGA-R 19″ 3U Rittal Ripac · TRM-PGA-W Rittal AX 500×500×210 IP66
sample6 mm Swagelok-type · 300–500 sccm · 0.9–1.1 bar · < 90 °C
IR·SF₆
stationary NDIR transmitter
F-gasroom & leak monitoringGIS / substations
Tremon IR·SF₆
gasSF₆ + refrigerants (F-gas)
range0–1000 / 0–2000 ppm (0–6000 / 0–12000 mg/m³)
optics2-beam + reference · heated cell
responsewarm-up 60 s · t₉₀ ≤15 s
interfaceRS-485 Modbus RTU
buildIP65 · −40…+60 °C · aluminium
TRM-EX
stationary field gas analyzer · Ex
methane LDARworkplace safety · ATEXhazardous areas
Tremon TRM-EX
principleelectrochemical · thermocatalytic · infrared · semiconductor
gasestoxic · combustible (%LEL) · O₂ · CO₂ · HC · refrigerants
variantsTRM-EX-E · TRM-EX-CT · TRM-EX-IR · TRM-EX-SMC
output4–20 mA · RS-485 Modbus RTU · relay opt.
Ex markingEx db IIC T6 Gb X · Ex tb IIIC T85°C Db X
buildIP65 · SS316 sensor · −40…+60 °C · 12–24 V DC

L3Systems — collect, alarm, report

Controllers and cabinets that turn field readings into alarms, records and SCADA data — the layer that makes compliance repeatable.

GDC
gas detection controller · cabinet
IED · CEMSmulti-point alarmsSCADA
Tremon GDC
functionmulti-level gas monitoring & alarm controller
field devicesup to 30 analyzers per cabinet
architecture3 levels · field → GDC cabinet → SCADA
protocolsModbus RTU / TCP/IP · IEC 60870-5-104
I/Oup to 112 relay outputs · 4–20 mA · RS-485
enclosure600×600×250 mm · 26 kg · IP65 · 230 V AC
GDC-S52
sample-extraction system · GDC family
SF₆ · GIS roomsF-gas 2024/573multi-point
Tremon GDC-S52
functionsequential aspiration of gas samples from remote points to one analyzer
sample pointsup to 12 impulse lines · 8 mm PU tube · 20 m/s
automationTremon Lorentz PLC · touch-panel · 16 relay outputs
protocolsModbus TCP · IEC 60870-5-104 (PRP) · RS-485 Modbus RTU
pneumatics5.5 bar compressed air · built-in cabinet & line leak tests
enclosure1000×600×250 mm · 25 kg · IP65 · −40…+60 °C · dual feed ATS
GASPOD
automated gas-cylinder cabinet
semiconductortoxic & flammable gases
Tremon GASPOD
purposesafe storage & supply of inert · flammable · toxic gases
usesemiconductor fab · energy · research
controlTouch-Screen ≥10″ · EMO · status column
safetygas-leak · fire · exhaust · door monitoring
interfaceModbus TCP (Ethernet) · discrete I/O
buildIP54 · 2550×610×610 mm · up to 4 × 50 L · 300 bar
Gas × technology

What each channel measures

One matrix, from our own datasheets: the measuring principle that serves each gas group and where it is typically used.

GasNDIR (IR)Thermocatalytic (CT)Electrochemical (E)Semiconductor (SMC)Typical use
CO₂
0–5000 ppm → 100 vol%
···biomethane · CEMS · IAQ · CBAM
CH₄ · hydrocarbons
0–100 %LEL · vol%
··methane LDAR · biomethane · safety
SF₆
0–1000 / 0–2000 ppm · density
··F-gas · GIS / switchgear
Refrigerants R-134a · R-125 · R-22 · R-227ea · R-407c…
ppm ranges
··F-gas · leak detection
CO
0–300 / 500 / 1000 ppm
···safety · CEMS (E)
SO₂ · NO · NO₂ · N₂O
ppm ranges
···emissions · safety
O₂
0–25 vol%
···confined space · inerting
H₂S · NH₃ · HCN · Cl₂ · HF · HCl
ppm ranges
···toxic gas safety
H₂
0–500 / 1000 / 2000 ppm · %LEL
··hydrogen · battery rooms
SiH₄ · AsH₃ · PH₃ · B₂H₆ · GeH₄ · WF₆ …
ppb–ppm
···semiconductor · GASPOD / GDC
Solvents · alcohols · aromatics (C₂–C₉)
%LEL
···process safety
Honest boundary. NDIR is our core and covers CO₂, CH₄/hydrocarbons, SF₆ and refrigerants. O₂, H₂, Cl₂ and H₂S have no usable IR absorption (or are masked by water) — those are served by the electrochemical, thermocatalytic and semiconductor channels of the TRM-EX. Full gas lists with ranges are in each datasheet.
Need a different gas, range or form factor?
One gas or several — scoped to the rule and the decision your reading protects.
Spec your channel →See applications →